This unit is designed to operate at outdoor ambient temperatures from 55 to 120 deg F in cooling from 10 to 66 deg F in heating (heat pumps only). Only AHRI® approved indoor matches are approved for use with these models.
TRANE® Split System Heat Pump, Series: XV18, Model: 4TWV8060A1, 208 to 230 VAC, 37 A, 60 Hz, 1 Phase, 60000 Btu/hr Heating, 18 SEER, Brazed Connection, Scroll Compressor, R-410A Refrigerant, 5 ton Tonnage, 3/8 in Liquid Line, 1-1/8 in Suction Line, 54 to 65 dB Sound Level, Steel, Galvanized/Powder-Coated, 10 to 66 deg F, 51.1 in H x 35.1 in W x 38.7 in D
Model |
: |
4TWV8060A1 |
Voltage Rating |
: |
208/230 VAC |
Amperage Rating |
: |
37 A |
Frequency Rating |
: |
60 Hz |
Phase |
: |
1 ph |
SEER Rating |
: |
18 |
Connection Type |
: |
Brazed |
Compressor Type |
: |
Scroll |
Refrigerant Type |
: |
R-410A |
Tonnage |
: |
5 ton |
Liquid Line Size |
: |
3/8 in |
Suction Line Size |
: |
1-1/8 in |
Sound Level |
: |
65 dB |
Material |
: |
Steel |
Finish |
: |
Galvanized/Powder-Coated |
Temperature Rating |
: |
10 to 66 deg F |
Dimensions |
: |
51.1 in H x 35.1 in W x 38.7 in D |
- This outdoor unit contains the ComfortLink™ II digital communication with two wire connection to outdoor and plug-n-play setup
- Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder-paint on all louvered panels and prepaint on all other panels, corrosion and weatherproof CMBP-G30 DuraTuff™ base
- Refrigeration system controls include condenser fan, compressor contactor and high and low pressure switches, a factory supplied, field installed filter is standard
- Inverter driven scroll compressor with 25 to 100% output capacity on heat pumps and 30 to 100% out put capacity on air conditioners, noise enclosure minimizes sound levels and built-in compressor protection protects compressor will reduce operating speed and current draw to maintain operation while protecting the compressor
- The SpineFin™ outdoor coil provides low air flow resistance and efficient heat transfer, the coil is protected on all four sides by louvered panels
- As manufactured, this system has built-in freeze protection that will allow cooling operation below 55 deg F but will reduce capacity or shutdown completely to prevent operation under adverse conditions
- The 1050/950/850 Control is required and provides Plug-n-Play set up and 3 wire connection
-
Catalog
https://cx1content.unilogcorp.com/cx1/view/api/asset/v1/dam/assets/ITEM/DOC/file/267/TRANE_4TWV8037A1000B_Catalog.pdf
-
Instruction/Installation Manual
https://cx1content.unilogcorp.com/cx1/view/api/asset/v1/dam/assets/ITEM/DOC/file/267/TRANE_4TWV8037A1000B_Instruction_Installation_Manual.pdf
-
Service Manual
https://cx1content.unilogcorp.com/cx1/view/api/asset/v1/dam/assets/ITEM/DOC/file/267/TRANE_4TWV8037A1000B_Service_Manual.pdf
-
Warranty Information
https://cx1content.unilogcorp.com/cx1/view/api/asset/v1/dam/assets/ITEM/DOC/file/267/TRANE_4TTR7036A1000B_Warranty_Information.pdf